lndustrial Charger(DC UPS)

uXcel mini Battery Charger

The industrial battery charger provides a advanced solution with Small substations and power plants system. Rectifier battery charger combines reliability from naturally cooled thyristor-based rectifier with proven microprocessor control technology to offer the best performances in any electrical and environmental conditions. It's suitable for charging VRLA sealed lead acid, Lithium battery as well as maintenance free nickel-cadmium batteries.



  • lead time:

    Normally 4~6 weeks
  • brand:

    EverExceed
  • Nominal DC voltage(Output):

    24/48/110/125/220/240/400V
  • Nominal DC current(output):

    1-20A
  • Input AC voltage:

    Single phase 1×230V(220,240)/Three phase 3×400V(380,415)
  • Battery type:

    Lead acid batteries, nickle cadmium batteries, lithium batteries
  • Communication:

    RS232/RS485 Modbus, TCP/IP Ethernet (optional)
  • OEM/ODM Service:

    Yes, customized service available
  • Certificates:

    CE, EN61000, IEC60146
  • Features
  • TECHNICAL DATA
  • SUCCESSFUL CASES
  • Download
  • Factory
  • Video
  • FAQ


EverExceed| A global leading manufacturer of customized industrial battery charger;

Comprehensive Industrial Chargers for Diversified DC Power Solution

We can customize More flexible, More reliable, More affordable industrial battery chargers for lead acid batteries, nickel cadmium batteries and lithium batteries.






Technical features:






 

Large LCD display

Leading Technology

                      High Reliability and High MTBF 
User friendly operation with large LCD display, optional touch screen with the choices of 8 languages ensure easy maintenance and operation. Smart communication and remote monitoring.
The embedded micro-computer controller processes signals 10 times faster than standard analog methods.
Fully automatic battery management with "four remote"
functions meeting requirements of untended duty control.




Isolation transformer

Flexible maintenance and Reduced MTTR

                        Long design life up to 20+years
Filter more than 3 harmonics in the power grid interference to the system equipment, while strengthening the operation security of the system.

The design make it easy for front-access to all vital modules modules of the charger

Versatile constant voltage and constant current charging modes

Smart communication and Remote Monitoring through isolated RS232, RS485, Ethernet. Full data logging.


 System design life up to 20+ years in continuous operation under the condition of appropriate maintenance.


Flexibly customized
Ruggedized solutions
Complete power protection solutions

Power solutions to perfectly meet the specific requirements of customer’s industrial applications.

To withstand harsh environments, extreme temperatures, humidity, dust and vibrations etc. Up to IP55 protection.
Including switchgear, DC distribution, monitoring suite.


Protection and alarm

• Overload/short circuit

• Input and output fuse or breaker

• Over temperature protection

• Over DC voltage/under DC voltage

• Ground alarm

• Dropping diode(optional)




Indications

• Mains on / Manual

• Run / Mains fault

• BAT MCB on / Load MCB on

• Float / Boost

• Ground fault

• Dropping diode(optional)





Applications:

Our parters

INPUT
Nominal input voltage

120/208/220/230/240VAC±10% ,Single phase (Other voltages can be customized)

Frequency 50/60Hz±5%
OUTPUT
Output voltage 24V, 30V, 48V, 50V
Output voltage range 100%-150% nominal voltage
Output current 10A, 15A, 20A
Ripple voltage Within 5% RMS at full load&max.DC voltage
Current Limited to 110% of In
Output Regulation ±1% for 198 to 242VAC supply voltage
Analog measurements Output voltmeter and amperemeter,load voltmeter and amperemeter(Dropping diode type)
Local alarms Mains fault,output under voltage,output overvoltage,ground fault
Mode of operation Boost/float, Manual/Automatic
Protections Overload/short circuit,Charger fuses,Battery and load breaker,Over temperature protection
Available languages English,Spanish(Optional)
GENERAL INFORMATION
Cabinet Dimession
Battery inside cabinet:1100H*580W*600D
Battery outside cabinet:350H*440W*500D
Degree of protection IP20
Color RAL7035
Operating Temperature 0℃ to 45℃,Up to 55℃ with power derating
Humidity 10% to 95% non condensing
Installation height Up to 1000m over sea level. Up to 3000m with power derating
Connection Bottom
OPTIONAL
Communication RJ45,Modbus TCP/IP
RS485,Modbus RTU
DNP3.0
Volt-free contacts
Remote monitoring










If you need to download files, you need to register as our member first ! log in / registered

  • EverExceed Smart charger V1.0.pdf


How are “equalize”, “boost” and “fast charge” charging different?

Each of these terms describes the same function of the charger where the charger temporarily elevates the battery’s voltage above the float level. There are different uses for elevated charge voltage, as shown below:

Commonly understood meaning of the term

Equalize – Periodic “topping up” of battery capacity, and correct cell capacity differences

Boost – Can refer to “equalize,” “fast charge,” and sometimes both

Fast charge – Faster recharge of a discharged battery

 

What does “equalize” charging do, and why is it needed?

All batteries, even those assembled into unitized blocks, are all built of individual battery cells connected in series to obtain the required DC voltage. Like all manufactured products, there is variation between the capacities of each cell in the battery. As the battery ages this variation increases. Since the battery is a chain of cells that is only as strong as the weakest link some scheme is required to ensure that all cells stay at peak capacity.

A scheme called “equalizing” is commonly used in both lead-acid and nickel cadmium batteries. Equalizing temporarily elevates the charging voltage of the entire battery string above the normal “float” voltage. The elevated charging voltage allows all cells, including the weak ones, to accept more current from the charger than they would at float voltage. A consequence of the elevated equalize voltage is that all cells in the battery are overcharged. This is acceptable for short periods provided the battery has sufficient electrolyte.

Overcharging greatly increases the rate at which the water in battery electrolyte is electrolyzed into oxygen and hydrogen gas. Since low electrolyte level will permanently damage the battery it is important to limit when, and for how long, the battery is charged at the equalize voltage.

 

What is “fast charging”?

Batteries, like all electrical conductors, suffer from resistance in their conductive metals. Ohm’s law says that resistance increases in proportion to current flow through the battery (or any other imperfect conductor). This means that the more amperes of charge we attempt to apply to the battery the more will be lost due to internal heating.

“Fast charging” temporarily increases the charger’s output voltage to compensate for the battery’s internal resistance. This allows the battery to continue accepting maximum current from the charger for a longer time – instead of reducing its charge acceptance early as it would if charged at normal float voltage.

 

What is the correct charging voltage?

The value of both float and equalize/boost/high rate voltages is determined by the battery manufacturer, and depends on the chemistry and construction of the battery. Deviating from the recommended values, except where needed to adjust for temperature, will under or overcharge the battery – both of which will reduce the battery’s life and performance.

 

How do you know when the charger should operate in float or equalize mode?

Regardless of the intended purpose of increasing the charger’s voltage there needs to be a way to start and end charging at voltage higher than float.

The most common control methods are shown below.

Control method: Manual switch

· Advantage: Simple, cheap

· Disadvantage: High risk of forgetting unit is operating at elevated charging voltage

· Comment: Not recommended

Control method: Manually initiated timer

· Advantage: Simple, and automatically terminates charge

· Disadvantage: Requires user intervention

· Comment: No way to know when battery would benefit from elevated voltage charge. No way to know what the right time setting is

Control method: Automatically initiated timer

· Advantage: Suited for remote sites where users do not visit frequently

· Disadvantage: Time must be pre-programmed.

· Comment: The correct pre-programmed time cannot be predicted since depth of discharge is likely to vary

Control method: Automatic initiation with battery-determined end

· Advantage: Termination of elevated charge voltage is based on battery needs, not a program

· Disadvantage: High continuous current can trick system into staying at elevated voltage too long

When is battery temperature compensation needed? How important is it?

It is well known that all storage batteries – vented or VRLA lead acid or nickel cadmium – require different charging voltage at different temperatures. When cold, the battery requires higher than normal charge voltage in order to deliver maximum possible performance. When warm, charging voltage must be reduced to prevent overcharging and consequent loss of electrolyte.

When the battery is located in a well-controlled environment temperature compensation adds little value. In contrast, temperature compensation is absolutely essential when batteries are located in outdoor cabinets or other areas subject to extremes of temperature. These facts illustrate the value of temperature compensation:

· When a battery that is 90 degrees F in temperature is charged at the correct voltage for 50 degrees F it will be boiled dry in three months.

· When a battery 20 degrees F is charged at the correct voltage for 50 degrees F it will fail to charge – and thus fail to deliver its specified performance.

Using a charger equipped with automatic temperature compensation can prevent both of these problems.

 

 

I am thinking about disabling the temperature compensation feature because the charger and battery are not in the same location, and I am worried about overcharging the battery.

Temperature compensation should only be disabled if the batteries can always be guaranteed to be at room temperature (25C, or 77F).

Remote temperature sensing (RTS) is the correct way to provide temperature compensated charging where battery and charger are in different ambients. It is always preferable to both non-compensated and locally compensated charging. Using a sensor attached directly to the battery eliminates all variables of charger temperature and different room temperatures. There is no downside to using RTS. Compared with either disabled, or in-charger temperature compensation, RTS will absolutely, positively increase battery performance to the maximum possible. Regardless of conditions, RTS causes the charger to deliver the exact voltage needed by the battery.

EVEREXCEED made a provision to disable temperature compensation mainly for customer acceptance testing – to demonstrate that the voltage setting agrees with the actual output voltage. This can be difficult to determine in a temperature compensated charger.

EVEREXCEED designed its RTS system so that if the remote sensor is damage or becomes disconnected the charger reverts to non-compensated operation. This change is indicated on the charger front panel.

 

Why do nickel cadmium batteries need to be “boost” charged?

Nickel cadmium batteries offer the highest reliability of any battery, and are more resistant to mechanical and environmental abuse than lead-acid batteries. They do, however, need special charging in order to deliver maximum performance.

If a nickel cadmium battery is charged only at the float rate it will typically deliver only about 70% of its rated capacity. This is a more serious problem for high rate applications, such as engine starting, where even small reductions in capacity have a significant impact on performance.

The most effective way to insure full capacity is available in a nickel cadmium battery is to periodically charge it at an elevated voltage. This can be initiated either manually or automatically, depending on the charger. Automatic equalization is easier to use, and reduces the risk of forgetting to switch back to float voltage.

 

 

Leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
r
EverExceed | Empower, Energize, Exceed the Energy you Expect forever;
2V AGM battery

Modular Max Range VRLA Battery

EverExceed Modular Max Range Valve Regulated Lead Acid (V.R.L.A.) batteries are designed for the long standby back-up power requirements of wireless / PCS telecommunications, MTSOs, central offices, utilities, switchgear and control applications. Our advanced AGM absorbed electrolyte technology coupled with thick positive plates and a welded / epoxy, dual post seal ensures reliable performance, safety, outstanding battery life and value.
2V OPzV tubular gel battery

Tubular OPzV Range VRLA Battery

EverExceed state-of-the-art manufacturing facilities with wealthy experience ensure it's tubular OPzV gelled batteries reliable performance, safety, outstanding battery life and value. Each cell is 100% factory tested. EverExceed tubular OPzV batteries can be used in float or deep cycle (1500 x 80%) service and have a design life of 20 years at 20°C. EverExceed tubular OPzV batteries can be stored up to 2 years at 20°C without fresh charging.
Rectifier Battery Charger

uXcel Ultra Series Redundancy Rectifier Battery Charger

The EverExceed uXcel Ultra redundancy charger (DC UPS) is a new type charger for battery. This charging system is made by two independent charging loop in parallel which can carry out the redundancy charge function. This system is controlled by digital intelligence with multi charging mode, simple operation and reliability.  There is no phase sequence requirement. The transformer is made by high strength paint copper and it can achieve H grade high temperature resistance and isolation. The power units are made by aluminum profile and high-power disc type thyristor units with high performance and reliability. Available in single and three phase up to 220kW and using ultra rugged phase controlled technologies, this series is ideal for all industrial applications including substation battery systems and DC UPS.
Energy storage lithium battery

12.8V 150ah Lithium Ion Battery Pack LiFePO4 Battery to Replace SLA Battery

EverExceed LDP Series Lithium Iron Phosphate ( LiFePO4 ) batteries are developed to deliver high efficiency energy output compared to equivalent lead acid batteries. They are able to accept continuous high rate charging amps which make the battery fully charged in short time and improve the load service efficiency significantly. The built-in advanced BMS ensures intelligent automatic protection against over voltage, over current, over discharge, over temperature.
1.2V rechargeable maintenance free nicd battery

EBL Pocket Plate Range NiCd Battery

EverExceed pocket type nickel cadmium battery has been supplied stable and reliable battery solution for many industrial power applications. Our block batteries function in a wide range of temperatures, resist electrical abuse, shock and vibrations and need only basic maintenance. This ensures a low total cost of ownership (TCO) over a life cycle that can last 20 years or more.
Are you looking for more information about EverExceed's  professional products and solutions?  Our expert team is always here to help. Please fill in the form and our sales representative will contact you shortly. EverExceed | Empower, Energize, Exceed the Energy you Expect forever.
copyright © 2024 EverExceed Industrial Co., Ltd.all rights reserved.
leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact