MODEL
|
PL3 6KS
|
PL3 6KL
|
PL3 10KS
|
PL3 10KL
|
PL3 15KS
|
PL3 15KL
|
PL3 20KS
|
PL3 20KL
|
Capacity
|
6kVA/6kW
|
6kVA/6kW
|
10kVA/10kW
|
10kVA/10kW
|
15kVA/15kW
|
15kVA/15kW
|
20kVA/20kW
|
20kVA/20kW
|
Phase
|
1 Phase in/1 Phase out
|
INPUT
|
Nominal Voltage
|
208/220/230/240VAC (L-N Voltage), L+N+PE
|
Input Voltage Range
|
176~300VAC (L-N voltage)@100%load; 176~110VAC, linearly derating from 100% to 50% load
|
Input Frequency Range
|
50/60±6Hz
|
Input Power Factor
|
>0.99
|
Input Current Distortion (THDi)
|
<5%
|
Bypass Voltage Range
|
-40%~20% of nominal voltage, adjustable
|
OUTPUT
|
Nominal Votage
|
208/220/230/240VAC, L+N+PE
|
Voltage Regulation
|
± 1 %
|
Nominal Frequency
|
50/60Hz, adjustable
|
Output Frequency
|
Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz
|
Output Power Factor
|
1
|
Output Voltage Distortion (THDu)
|
≤2%@linear load; ≤5%@non-linear load
|
Transfer Time
|
Line mode to Battery mode, 0ms; Inverter to Bypass, 0ms (Synchronized);
Bypass to Inverter, 0ms(Synchronized); ECO to Battery Mode, 2ms (Typical Time)
|
Crest Ratio
|
3:1
|
Overload Capacity
(Line Mode)
|
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
30 min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
200 ms @ >150% load
|
30 min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
500 ms @ >150% load
|
Overload Capacity (Battery Mode)
|
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
500 ms @ >150% load
|
Output Short Circuit Protection
|
Line Mode: Current limitation; Battery Mode: Current limitation; Bypass Mode: Breaker
|
BATTERY
|
Battery Type
|
Sealed Lead Acid Maintanance Free (VRLA)
|
Nominal Voltage
|
192~240VDC, adjustable
|
Charging Voltage
|
Floating Charge, 2.25V/cell; Boost Charge, 2.35V/cell
|
Battery Number&Capacity
|
16 pcs,
12V/7Ah
|
External
|
16 pcs,
12V/9Ah
|
External
|
16 pcs,
12V/9Ah
|
External
|
16 pcs*2strings, 12V/9Ah
|
External
|
Charging Current
|
1A
|
1~12A,
adjustable
|
1A
|
1~12A,
adjustable
|
1A
|
1~12A,
adjustable
|
1~2A, adjustable, default 2A
|
1~12A,
adjustable
|
Charging Mode
|
Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable)
|
Typical Recharge Time
|
9 hours recharge to 90%
|
Depending on the capacity of external batteries
|
9 hours recharge to 90%
|
Depending on the capacity of external batteries
|
9 hours recharge to 90%
|
Depending on the capacity of external batteries
|
9 hours recharge to 90%
|
Depending on the capacity of external batteries
|
Battery Protection
|
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection,
Over Current Protection; Battery Deep Discharge Protection
|
EFFICIENCY
|
Line Mode
|
95.5% (Max)
|
94% (Max)
|
Battery Mode
|
95% (Max)
|
92% (Max)
|
ECO Mode
|
98.5%
|
98%
|
INDICATORS
|
LCD Panel
|
UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code
|
Audible Alarm
|
Utility Failure, Battery Voltage Low, Overload, System Fault
|
MANAGEMENT
|
Interface
|
RS232 ,USB, Parallel Card, EPO Port, SNMP Card (Optional), Relay Card (Optional)
|
ENVIRONMENT
|
Operating Temperature
|
0~40℃
|
Operating Humidity
|
0~95% RH, non-condensing
|
Storage Temperature
|
-15~60℃ (Battery: 0-40℃)
|
Altitude
|
<1000m, derating 1% per 100m from 1000 ~ 2000m
|
Noise (1Meter Away)
|
<55dB
|
<60dB
|
PHYSICAL
|
Dimension
(W*D*H, unit:mm)
|
250x523x602
|
190x437x322
|
250x523x602
|
190x437x322
|
251*635*315
|
215*635*722
|
251*635*315
|
215*635*722
|
Net Weight (kg)
|
68
|
15
|
75
|
17
|
87
|
21
|
122
|
23
|
Color
|
Black ( RAL9004)
|
STANDARDS
|
Safety
|
IEC 62040-1:2017
|
EMC
|
IEC 62040-2:2018
|
Performance
|
IEC 62040-3:2011
|
Battery
|
IEC 60896-22:2004
|