MODEL
|
PL31 10KS
|
PL31 10KL
|
PL31 15KS
|
PL31 15KL
|
PL31 20KS
|
PL31 20KL
|
Capacity
|
10kVA/10kW
|
10kVA/10kW
|
15kVA/15kW
|
15kVA/15kW
|
20kVA/20kW
|
20kVA/20kW
|
Phase
|
3-Phase
in/1 Phase out
|
INPUT
|
Nominal Voltage
|
380/400/415Vac
(L-L voltage), 3Ph+N+PE
|
Input Voltage Range
|
190~520Vac
(L-L voltage)
|
Input Frequency Range
|
50/60±6Hz
|
Input Power Factor
|
>0.99
|
Input Current Distortion (THDi)
|
≤5%
|
Bypass Voltage Range
|
-40%~20%
of nominal voltage, adjustable
|
OUTPUT
|
Nominal Votage
|
208/220/230/240Vac,
L+N+PE
|
Voltage Regulation
|
± 1 %
|
Nominal Frequency
|
50/60Hz,
adjustable
|
Output Frequency
|
Line
mode:50/60±1/2/3/4/5Hz , adjustable ; battery mode: 50/60±0.01 Hz
|
Output Power Factor
|
1
|
Voltage Distortion
(THDu)
|
≤2%@linear
load; ≤5%@non-linear load
|
Transfer Time
|
Line
mode to Battery mode, 0ms; Inverter to Bypass, 0ms (Synchronized); Bypass to
Inverter,
0ms(Synchronized); ECO to Battery Mode, 2ms (Typical Time)
|
Crest Ratio
|
3:1
|
Overload Capacity (Normal Mode)
|
30
min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
500 ms @ >150% load
|
Overload Capacity (Battery Mode)
|
10
min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
500 ms @ >150% load
|
Overload Capacity (Bypass Mode)
|
Depending
the input breaker (63A)
|
Depending
the input breaker (63A)
|
Depending
the input breaker (125A)
|
Depending
the input breaker (125A)
|
Depending
the input breaker (125A)
|
Depending
the input breaker (125A)
|
Output Short Circuit Protection
|
Line
Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode:
Breaker
|
BATTERY
|
Battery Type
|
Sealed
lead acid maintenance free
|
Nominal Voltage
|
192~240Vdc,
settable
|
Charging Voltage
|
Floating
Charge, 2.25V/cell; Boost Charge, 2.35V/cell
|
Battery Number&Capacity
|
16
pcs, 12V/9Ah
|
External
|
16
pcs*2strings, 12V/9Ah
|
External
|
16
pcs*2strings, 12V/9Ah
|
External
|
Charging Current
|
1A
|
1~12A,
settable
|
2A
|
1~12A,
settable
|
2A
|
1~12A,
settable
|
Charging Mode
|
Two
Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable)
|
Typical Recharge Time
|
9
hours recharge
to 90%
|
Depending
on the capacity of external batteries
|
9
hours recharge
to 90%
|
Depending
on the capacity of external batteries
|
9
hours recharge
to 90%
|
Depending
on the capacity of external batteries
|
Battery Protection
|
Battery
Leakage<500µA, Over Voltage Protection, Under Voltage Protection,
Over Current Protection; Battery Deep Discharge Protection
|
EFFICIENCY
|
Line Mode
|
94%
(Max)
|
Battery Mode
|
92%
(Max)
|
ECO Mode
|
98%
(Max)
|
INDICATORS
|
LCD Panel
|
UPS
status, Battery Level, Load Level, Input/Output/Battery Voltage,
Fault&Alarm Code
|
Audible Alarm
|
Utility
Failure, Battery Voltage Low, Overload, System Fault
|
MANAGEMENT
|
Interface
|
RS232
,USB, Parallel Card, EPO Port, SNMP Card (Optional), Relay Card (Optional)
|
ENVIRONMENT
|
Operating Temperature
|
0~40
℃
|
Operating Humidity
|
0~95%
RH, non-condensing
|
Storage Temperature
|
-15~60℃
(Battery: 0-40 ℃)
|
Altitude
|
<1000m,
derating 1% per 100m from 1000 ~ 2000m
|
Noise (1Meter away)
|
<60dB
|
PHYSICAL
|
Dimension
(W*D*H, unit:mm)
|
250*500*940
|
250*500*620
|
250*500*940
|
250*500*620
|
250*500*940
|
250*500*620
|
Net Weight (kg)
|
73
|
32
|
99
|
33
|
100
|
35
|
Color
|
Black
( RAL9004)
|
STANDARDS
|
Safety
|
IEC
62040-1:2017
|
EMC
|
IEC
62040-2:2018
|
Performance
|
IEC
62040-3:2011
|
Battery
|
IEC
60896-22:2004
|