MODEL
|
PL3 RM1KS
|
PL3 RM1KL
|
PL3 RM2KS
|
PL3 RM2KL
|
PL3 RM3KS
|
PL3 RM3KL
|
Capacity
|
1kVA/1kW
|
1kVA/1kW
|
2kVA/2kW
|
2kVA/2kW
|
3kVA/3kW
|
3kVA/3kW
|
Phase
|
1 Phase in/1 Phase out
|
INPUT
|
|
Nominal Voltage
|
208/220/230/240VAC (L-N Voltage), L+N+PE
|
Input Voltage Range
|
110~300VAC
|
Input Frequency Range
|
50/60±6Hz
|
Input Power Factor
|
>0.99
|
Input Current Distortion (THDi)
|
≤4%(linear load);≤5%(non-;linear load)
|
Bypass Voltage Range
|
-40%~20% of nominal voltage, adjustable
|
OUTPUT
|
|
Nominal Votage
|
208/220/230/240VAC , L+N+PE
|
Voltage Regulation
|
± 1 %
|
Nominal Frequency
|
50/60Hz, adjustable
|
Output Frequency
|
Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz
|
Output Power Factor
|
1
|
Output Voltage Distortion (THDu)
|
≤2%@linear load; ≤5%@non-linear load
|
Transfer Time
|
Line mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized);Bypass to Inverter, 4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time)
|
Crest Ratio
|
3:1
|
Overload Capacity
(Line Mode)
|
30 min @ 102%~110% load;10 min @ 110%~130% load;30s @130%~150% load;200 ms @ >150% load
|
Overload Capacity
(Battery Mode)
|
1 min @ 102%~110% load;10s @ 110%~130% load;3s @130%~150% load;200 ms @ >150% load
|
Overload Capacity
(Bypass Mode)
|
Depending the input breaker (10A)
|
Depending the input breaker (20A)
|
Output Short Circuit Protection
|
Line Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode: Breaker
|
BATTERY
|
|
Battery Type
|
Sealed Lead Acid Maintanance Free (VRLA)
|
Nominal Voltage
|
24VDC
|
36VDC
|
48VDC
|
72VDC
|
72VDC
|
96VDC
|
Charging Voltage
|
Floating
|
Battery Number&Capacity
|
2 pcs, 12V/9Ah
|
External
|
4 pcs, 12V/9Ah
|
External
|
6pcs, 12V/9Ah
|
External
|
Charging Current
|
1A-4A,adjustable, default 1A
|
1~12A, adjustable
|
1A-4A,adjustable, default 1A
|
1~12A, adjustable
|
1A-4A,adjustable, default 1A
|
1~12A, adjustable
|
Charging Mode
|
Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable)
|
Battery Protection
|
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection, Over Current Protection;Battery Deep Discharge Protection
|
EFFICIENCY
|
|
Line Mode
|
94.5% (Max)
|
95.5% (Max)
|
95.5% (Max)
|
Battery Mode
|
88.5% (Max)
|
89.5% (Max)
|
91.5% (Max)
|
ECO Mode
|
98%
|
INDICATORS
|
|
LCD Panel
|
UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code
|
Audible Alarm
|
Utility Failure, Battery Voltage Low, Overload, System Fault
|
MANAGEMENT
|
|
Interface
|
RS232 ,USB, EPO Port, SNMP Card (Optional), Relay Card (Optional)
|
ENVIRONMENT
|
|
Operating Temperature
|
0~40℃
|
Operating Humidity
|
0~95% RH, non-condensing
|
Storage Temperature
|
-15~60℃ (Battery: 0-40℃)
|
Altitude
|
<1000m, derating 1% per 100m from 1000~ 2000m
|
Noise (1Meter Away)
|
<50dB@ 1 meter away
|
PHYSICAL
|
|
Dimension(W*D*H, unit:mm)
|
440*379*86
|
440*379*86
|
440*568*86
|
440*450*86
|
445*560*86
|
440*450*86
|
Net Weight (kg)
|
8.6
|
4
|
18
|
8
|
24
|
10
|
Color
|
Black ( RAL9004)
|
STANDARDS
|
|
Safety
|
IEC 62040-1:2017
|
EMC
|
IEC 62040-2:2018
|
Performance
|
IEC 62040-3:2011
|
Battery
|
IEC 60896-22:2004
|