An industrial UPS (Uninterruptible Power Supply) provides backup power to critical industrial equipment during power outages, fluctuations, or disturbances. The specialized purpose of an industrial UPS system is to serve as a power protection device designed for industrial environments. Industrial UPS systems meet the demanding requirements of industrial environments, where power disruptions can cause equipment damage, production downtime, data loss, and safety hazards.
Industrial UPS
The UPS power supply generally refers to the uninterruptible power supply used in key equipment in the power, petrochemical, metallurgical and other industries. It generally uses phase-controlled rectification and high-frequency inverter technology.
Commercial UPS
Commercial UPS systems find applications in various industries, including data centers, insurance companies, financial institutions, and other sectors. High-frequency rectification and high-frequency inverter technology are commonly in most commercial UPS systems. These systems are with non-isolated mains, bypass, DC, and output configurations.
Difference between industrial UPS and commercial UPS
The primary difference between industrial UPS (Uninterruptible Power Supply) and commercial UPS lies in their design and intended applications. While both serve the purpose of providing backup power in case of electrical outages, they can meet different requirements and environments.
Capacity and Power
Low frequency UPS systems will handle higher power capacities than commercial UPS systems. Industrial environments often have larger power requirements due to the presence of heavy machinery, equipment, and critical processes. Commercial UPS systems, on the other hand, are typically for smaller-scale applications like offices, retail stores, or data centers with relatively lower power demands.
Robustness and Durability
Manufacturers build industrial UPS systems to withstand the harsh environments typically encountered in industrial settings. They are with ruggedenclosures, enhanced cooling mechanisms, and protection against dust, moisture, vibrations, and temperature fluctuations. Commercial UPS systems are generally for more controlled indoor environments and may not have the same level of durability as their industrial counterparts.
Reliability and Redundancy
The UPS systems often incorporate advanced features to ensure high reliability and availability of power. They may have redundant components, such as multiple power modules, hot-swappable batteries, and parallel configurations, to provide fault tolerance and minimize downtime. While commercial UPS
systems may offer some redundancy options, their primary focus is to provide reliable power to critical equipment rather than emphasizing extensive
redundancy.
How do I choose an UPS for industry?
Choosing the right UPS (Uninterruptible Power Supply) for industrial applications requires careful consideration of several factors. Here are some key factors to consider when selecting an industrial UPS:
Load Requirements
Start by determining the power capacity your critical equipment requires. Calculate the total power load, including both active power (measured in watts or kilowatts) and reactive power (measured in volt-amperes reactive or VARs). Ensure that the UPS capacity meets or exceeds the total load requirements to provide sufficient power backup.
Runtime Needs
Consider how long your critical equipment needs to remain operational during a power outage. Determine the required runtime based on the criticality of your
processes and the time it takes to restore utility power or start backup generators. Choose a UPS system with an appropriate battery backup capacity
to meet your desired runtime.
Power Quality Requirements
Evaluate the power quality needs of your sensitive equipment. Determine if voltage regulation, frequency stability, and harmonic distortion reduction are crucial for your applications. Certain industries, such as data centers or medical facilities, may have strict power quality requirements. Choose a UPS system that can provide the necessary voltage and frequency regulation, as well as high-quality waveform output.
Environmental Considerations
Assess the environmental conditions of your industrial facility. Consider factors such as temperature, humidity, dust levels, and vibrations. Select an industrial
UPS system that can withstand and operate reliably in the specific environmental conditions of your facility. Look for features like robust construction, thermal management systems, and protective measures against dust and moisture.
Total Cost of Ownership
Consider the upfront cost of the UPS system, as well as the long-term operational costs. Look beyond the initial purchase price and assess factors such as energy efficiency, battery replacement costs, and maintenance requirements. Opt for a UPS system that offers a balance between performance, reliability, and cost-effectiveness over its expected lifespan.
How to calculate industrial UPS backup time?
To calculate the backup time of an industrial UPS (Uninterruptible Power Supply) system, you need to consider the following factors:
Battery Capacity
Determine the capacity of the UPS system’s batteries, typically measured in ampere-hours (Ah) or kilowatt-hours (kWh). The UPS manufacturer typically provides this information regarding redundancy options and the primary focus of commercial UPS systems. Additionally, product specifications can also be a valuable source for obtaining such information.
Load Power Consumption
Calculate the power consumption of the equipment or load that will connect to the UPS system. This information is typically provided in watts (W) or kilowatts
(kW). If you are not aware of the load in watts, you can calculate the power consumption by utilizing the voltage and current values. You can employ the
formula: Power (in watts) = Voltage (in volts) x Current (in amperes).
Efficiency
Consider the efficiency of the UPS system. UPS systems have an efficiency rating that indicates the amount of power they convert from the battery to the load. The efficiency is usually expressed as a percentage. For example, when a UPS system has an efficiency of 90%, it means that 90% of the power drawn from the battery power the load, while lossing 10% the remaining as heat.
Derating Factor
Account for any derating factors or safety margins recommended by the UPS manufacturer. Derating factors may be necessary to ensure the longevity and proper functioning of the UPS system. These factors typically account for factors such as battery aging, temperature, and other variables.
Once you have gathered this information, you can use the following formula to
calculate the backup time:
Backup Time (hours) = Battery Capacity (Ah or kWh) x Efficiency (%) / Load Power Consumption (W or kW)