Blog
  • Why only online UPS topology provides mission critical load protection

    Why only online UPS topology provides mission critical load protection

    Sep , 09 2023
    Why does only online UPS topology provides mission critical load protection? Modern, static UPS systems are broadly classified into three design architectures: on-line, off-line and line interactive. This post describes and compares the three types and explains why – for truly critical loads – online ups topology is the only acceptable approach. Facility executives today face increased demands for...
    more
  • Lead-acid battery thermal runaway failure analysis when the battery is in the state of charge

    Lead-acid battery thermal runaway failure analysis when the battery is in the state of charge

    Sep , 04 2023
    Lead acid battery thermal runaway fault analysis When the battery is charged: There is a cumulative increase in battery temperature. When the heat accumulates to a certain extent during the warming process, the battery terminal voltage will suddenly decrease, forcing the current to increase suddenly, and the phenomenon of high battery temperature and damage to the battery is called thermal runaway...
    more
  • Important performance of the battery

    Important performance of the battery

    Sep , 04 2023
    1, electrical performance: (1) Rated capacity: 0.5C discharge, single battery discharge time is not less than 2h, battery pack discharge time is not less than 108min (95%); (2) 1C discharge capacity: 1C discharge, single battery discharge time is not less than 57min (95%), battery pack discharge time is not less than 54min (90%); (3) Low temperature discharge capacity: 0.5C discharge at -20℃, the ...
    more
  • UPS power supply power supply method and daily use precautions

    UPS power supply power supply method and daily use precautions

    Aug , 29 2023
    Today, whether it is a computer room or a data center, UPS power supply has played a vital position. When the UPS power supply is power supply in the municipal power, it is the role of the voltage regulator and filter to ensure the normal operation of the equipment; when the municipal power is interrupted, it can provide it by providing its DC power supply part (battery pack, diesel generator, etc...
    more
  • What are the characteristics of industrial UPS power supply

    What are the characteristics of industrial UPS power supply

    Aug , 29 2023
    Industrial UPS power supplies need to focus on the ability to operate in high-temperature environments. The design of components must adapt to the operational requirements of the industrial environment, adapt to high temperature and humidity, and also be able to cope with the corrosion of corrosive gases on the system. Under various operating conditions and continuous full load operation, industri...
    more
  • What is the main difference between EPS power supply and UPS power supply?

    What is the main difference between EPS power supply and UPS power supply?

    Aug , 25 2023
    Power supply is short for uninterruptible power supply, and its main function is to provide a stable and uninterruptible power supply for computers or some electronic devices by connecting the battery to the host. EPS power supply is the abbreviation of emergency power supply, usually used in emergency and accident lighting. Many people think that UPS power supply and EPS power supply and there is...
    more
  • Characteristics of using UPS power supply in computer rooms

    Characteristics of using UPS power supply in computer rooms

    Aug , 25 2023
    1.Due to the small initial load, there may be expansion in the later stage.Redundant design is required, and load shutdown is not allowed during expansion. 2.It can be used in conjunction with the original generator as a power sourceor distribution for fault configurations to ensure smooth power supply. 3.When a UPS fails, the battery of the faulty UPS can be transferred to othernormally operating...
    more
  • Why choose gel batteries?

    Why choose gel batteries?

    Aug , 22 2023
    The colloidal lead-acid battery is an improvement of the ordinary lead-acid battery with liquid electrolyte. The sulfuric acid electrolyte is replaced by a colloidal electrolyte, and the safety, power storage, discharge performance, and service life are improved compared with the ordinary battery. The colloidal lead-acid battery adopts a gel-like electrolyte; no free liquid is inside. Under the sa...
    more
  • Comparison of N-type and P-type cells for photovoltaic modules

    Comparison of N-type and P-type cells for photovoltaic modules

    Aug , 18 2023
    Photovoltaic cells are classified by substrate material and can be divided into P- and N-type batteries. A P-type battery refers to a battery with a P-type silicon wafer as the substrate, and an N-type battery refers to a battery with an N-type silicon wafer as the substrate. P-type silicon wafers have a simple production process and low cost, while N-type silicon wafers usually have a long life a...
    more
first page << 1 ... 18 19 20 21 22 ... 65 >> last page

a total of65 pages