Blog
  • How to choose UPS power supply for the computer room? (Part-1)

    How to choose UPS power supply for the computer room? (Part-1)

    Jun , 27 2022
    Enterprise data centers are becoming more and more important nowadays. How to ensure the stable operation of enterprise data centers has become a very critical factor. UPS is a standard accessory for many enterprises in data centers, so how to choose a UPS power supply suitable for enterprise applications? UPS classification: In general, UPS systems are divided into three categories, backup (or of...
    more
  • What is a Micro Data center?

    What is a Micro Data center?

    Aug , 01 2022
    When people think about the data center, they always think that in a very large building. There are a lot of cabinets neatly arranged, cabinets filled with servers, and servers are shining positive light. It looks cool. A data center is a dedicated space within a building, or a group of buildings used to house computer systems and associated components, such as teleco...
    more
  • UPS power supply power supply method and daily use precautions

    UPS power supply power supply method and daily use precautions

    Aug , 29 2023
    Today, whether it is a computer room or a data center, UPS power supply has played a vital position. When the UPS power supply is power supply in the municipal power, it is the role of the voltage regulator and filter to ensure the normal operation of the equipment; when the municipal power is interrupted, it can provide it by providing its DC power supply part (battery pack, diesel generator, etc...
    more
  • What is the difference between single phase and three phase UPS?

    What is the difference between single phase and three phase UPS?

    Oct , 16 2023
    When purchasing UPS for your business or organization, many factors should be taken into consideration, among which the choice of power supply between single phase UPS and three phase UPS is the foremost one. Though both of the UPS offer consistent backup power for dealing with unexpected situations, they have different roles. Here is a brief introduction of single phase vs three phase for those w...
    more
  • Introduction to Data Center Cabinet Head Cabinet

    Introduction to Data Center Cabinet Head Cabinet

    Nov , 03 2023
    The column head cabinet is a cabinet used to allocate and manage one or more columns of cabinets in the same computer room, and has protection functions. In power room, communication equipment room, and large network room, column head cabinet is necessary and also necessary. 1. Basic concept of column head cabinet A column head cabinet is a cabinet located at the top (first position, equivalent to...
    more
  • Telecom base station system introduction, application, characteristics

    Telecom base station system introduction, application, characteristics

    Jan , 13 2024
    The EverExceed ECB series telecommunications base station system is a new generation of outdoor multi energy integrated power supply system with MPPT function. Integrating EverExceed's superior communication power supply system, solar control system, and outdoor protective cabinet, we provide a green and energy-saving outdoor integrated multi energy power supply solution for outdoor communication ...
    more
  • Differences in communication serial ports

    Differences in communication serial ports

    May , 16 2024
    RS-232 and RS-485 are two common serial communication standards, with the following main differences between them: Different transmission methods: RS-232 adopts a single end transmission method, and its data signal is relative to the signal ground, usually used for point-to-point communication; RS-485 adopts differential transmission mode, allowing multiple transceivers to be connected on the bus,...
    more
  • Characteristics of UPS power supply used in server rooms

    Characteristics of UPS power supply used in server rooms

    May , 31 2024
    1. At the beginning of the bullying load is small, and expansion may occur at a later stage. There must be a redundant design that does not allow the load to be turned off during expansion. 2、It can be used in conjunction with the original generator as a power source or distribution for faulty configurations to ensure the smooth operation of power supply. 3, When a UPS failure, the faulty UPS batt...
    more
  • Differences in communication serial ports

    Differences in communication serial ports

    Jun , 22 2024
    RS-232 and RS-485 are two common serial communication standards, with the following main differences between them: Different transmission methods: RS-232 adopts a single end transmission method, and its data signal is relative to the signal ground, usually used for point-to-point communication; RS-485 adopts differential transmission mode, allowing multiple transceivers to be connected on the bus,...
    more
  • Installation and fixation of communication  cabinets and racks, regular maintenance and  auditing

    Installation and fixation of communication cabinets and racks, regular maintenance and auditing

    Aug , 03 2024
    Telecommunications infrastructure is the backbone of our  interconnected world. Behind the scenes, important equipment is stored in cabinets and racks to ensure seamless communication. However, without proper protection, these cabinets may become  vulnerable access points. In this comprehensive guide, we will explore the importance of protecting communication cabinets and  racks, wi...
    more

a total of1 pages

Are you looking for more information about EverExceed's  professional products and solutions?  Our expert team is always here to help. Please fill in the form and our sales representative will contact you shortly. EverExceed | Empower, Energize, Exceed the Energy you Expect forever.
copyright © 2025 Shenzhen EverExceed Industrial Co., Ltd.all rights reserved.
leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact