Blog
  • Negative electrode formula for high temperature performance of lead-acid battery

    Negative electrode formula for high temperature performance of lead-acid battery

    Jun , 07 2023
    Negative electrode formulation for high-temperature performance of lead-acid batteries (containing the first hydrogen evolution inhibitor Bi2O2CO3 and the second hydrogen evolution inhibitor ZnO). The basic formula of the negative electrode (number of weight) is: 100 parts lead powder, 8 ~ 11 parts dilute sulfuric acid, 9 ~ 13 parts deionized water, 0.06 ~ 0.14 parts short fiber, 0.10 ~ 0.20 parts...
    more
  • Preparation of reduced graphene oxide loaded lead oxide composites for lead carbon batteries

    Preparation of reduced graphene oxide loaded lead oxide composites for lead carbon batteries

    Jun , 07 2023
    Graphene is a new type of two-dimensional structure conductive material, which is composed of a single layer of carbon atoms and its basic structural unit is a six-membered ring structure, which has good chemical stability. Moreover, graphene has a high specific surface area, which not only provides a large reaction interface, but also improves the dispersion of surface nanomaterials. The high con...
    more
  • Self-discharge measurement of lithium batteries: resting and dynamic measurement methods

    Self-discharge measurement of lithium batteries: resting and dynamic measurement methods

    Jun , 14 2023
    The measurement methods of self-discharge of lithium-ion batteries are mainly divided into two categories: 1) static measurement method, which obtains the self-discharge rate by standing the battery for a long time; 2) Dynamic measurement method to realize the parameter identification of the battery in the dynamic process. Static measurement method At present, the mainstream self-discharge measure...
    more
  • Preparation of lead-reduced graphene oxide nanocomposites and their applications

    Preparation of lead-reduced graphene oxide nanocomposites and their applications

    Jun , 14 2023
    The shortcomings of lead-acid batteries are: low energy density and short cycle life. Lead sulfate formed by the negative plate of the lead-acid battery during the discharge process, after the battery is placed, the small particles of lead sulfate will be converted into large particles of lead sulfate, and the large particles of lead sulfate will not be converted into lead during the charging proc...
    more
  • Why Choose a Lithium-Ion UPS Battery?

    Why Choose a Lithium-Ion UPS Battery?

    Jun , 21 2023
    Although lithium-ion UPS systems have been around for decades, most people have been hesitant to choose this option because they were more expensive. With the onset of advanced battery technology, lithium-ion UPS systems have become much more attractive due to reduced pricing that rivals most standard, lead-acid battery UPS systems. UPS systems feature a state-of-the-art lithium iron phosphate (Li...
    more
  • Lithium battery capacity loss cause analysis

    Lithium battery capacity loss cause analysis

    Jun , 21 2023
    Lithium-ion batteries are the fastest-developing secondary batteries after cadmium-nickel and nickel-hydrogen batteries. Its high-energy properties make its future look bright. However, lithium-ion batteries are not perfect, and their biggest problem is the stability of their charge-discharge cycle. This paper summarizes and analyzes the possible causes of capacity attenuation of Li-ion batteries,...
    more
  • Selection of lead carbon-carbon addition

    Selection of lead carbon-carbon addition

    Jun , 30 2023
    The influence of chemical properties such as carbon material type and addition amount on battery performance was studied. Several different types of carbon materials (graphite, carbon black, activated carbon, etc.) were selected and tested for their effects on the negative electrode plate with additional amounts ranging from 0.2% to 4%, as well as hydrogen evolution inhibitors and adhesives. And c...
    more
  • What is a Rack UPS

    What is a Rack UPS

    Jul , 03 2023
    IT Racks Have Unique Power Requirements A rack uninterruptible power supply (UPS) system is designed for use within standard 19-inch IT racks or rack-based enclosures. Rack-based UPS systems must be designed to provide maximum power in compact packages with built-in batteries. A rack UPS generally uses from 1U to 12U of vertical rack space. Most rack UPS systems employ either online (double conver...
    more
  • How to maintain and extend UPS battery life?

    How to maintain and extend UPS battery life?

    Jul , 10 2023
    UPS batteries are used for several different things, but their main design is to ensure equipment is covered during a power failure before any backup power can kick in. It ensures that there is no lapse in power and those certain types of machinery and equipment can stay up and running without any gaps. They are often used on computers or in data centers to ensure that no valuable information...
    more
  • Transfer UPS load by static switch in Parallel ups

    Transfer UPS load by static switch in Parallel ups

    Jul , 10 2023
    One of the critical aspects of UPS systems is load balancing, and transferring the load between two or more UPS systems can significantly improve the reliability and efficiency of the system. In this blog, we will discuss the transfer of UPS load by using a static switch in parallel UPS. A static switch is an electrically operated switch that provides an automatic transfer of power between two or ...
    more
  • 7 Factors to Examine While Choosing a Lithium-Ion Battery Charger

    7 Factors to Examine While Choosing a Lithium-Ion Battery Charger

    Jul , 20 2023
    From confirming an acceptable input voltage to features like protection design and safe charging mode, these factors can help you select the right lithium-ion battery charger 1. Acceptable Input Voltage An input higher than the voltage sustenance capacity of the charger may cause damage to its internal components. Most countries use a battery charger design of the universal global voltage 110-230V...
    more
  • Explanation of power terms related to UPS power supply

    Explanation of power terms related to UPS power supply

    Jul , 28 2023
    Transient recovery time: The time required for the output voltage to recover to the specified range when the load suddenly changes (0-100%, 100% -0%), usually in milliseconds (ms). Filter: A device used to eliminate noise, filtering the input or output to obtain pure alternating current. Shielding: A means of isolating and blocking electromagnetic radiation using physical principles...
    more
first page << 1 ... 22 23 24 25 26 ... 32 >> last page

a total of32 pages

Are you looking for more information about EverExceed's  professional products and solutions?  Our expert team is always here to help. Please fill in the form and our sales representative will contact you shortly. EverExceed | Empower, Energize, Exceed the Energy you Expect forever.
copyright © 2024 EverExceed Industrial Co., Ltd.all rights reserved.
leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact