Blog
  • 7 Factors to Examine While Choosing a Lithium-Ion Battery Charger

    7 Factors to Examine While Choosing a Lithium-Ion Battery Charger

    Jul , 20 2023
    From confirming an acceptable input voltage to features like protection design and safe charging mode, these factors can help you select the right lithium-ion battery charger 1. Acceptable Input Voltage An input higher than the voltage sustenance capacity of the charger may cause damage to its internal components. Most countries use a battery charger design of the universal global voltage 110-230V...
    more
  • Explanation of power terms related to UPS power supply

    Explanation of power terms related to UPS power supply

    Jul , 28 2023
    Transient recovery time: The time required for the output voltage to recover to the specified range when the load suddenly changes (0-100%, 100% -0%), usually in milliseconds (ms). Filter: A device used to eliminate noise, filtering the input or output to obtain pure alternating current. Shielding: A means of isolating and blocking electromagnetic radiation using physical principles...
    more
  • Industrial UPS with Ride-through Protection

    Industrial UPS with Ride-through Protection

    Jul , 28 2023
    Introduction Electrical utilities use reclosers on medium voltage supply to isolate faults caused by events such as lightning strikes, tree branches across lines, or animals making contact with live wires. The result of a recloser operation is a momentary power outage, lasting for up to a few seconds. These outages can cause an unplanned production stoppage which can be very costly. When momentary...
    more
  • Effect of carbon black content on negative electrode performance of lead-acid battery

    Effect of carbon black content on negative electrode performance of lead-acid battery

    Aug , 04 2023
    VRLA battery is not ideal in electric vehicles because of its short life under deep charge and discharge cycle conditions. In recent years, with the improvement of positive plate grid materials, the cycle life of batteries has been improved, and the main reason for the failure of VRLA batteries for electric vehicles is the sulfation of the negative electrode. To this end, there are more studies on...
    more
  • 8 major functions of UPS power supply

    8 major functions of UPS power supply

    Aug , 18 2023
    The uninterrupted power supply is an uninterrupted power supply containing an energy storage device and a constant voltage constant frequencies with the inverter as the main part. Its main function is to provide uninterrupted power supply for single computers, computer network systems, or other power electronics equipment. When the city power input is normal, the UPS uninterrupted power supply pro...
    more
  • The Role of AC Capacitors in High Speed Circuits

    The Role of AC Capacitors in High Speed Circuits

    Aug , 18 2023
    1、Introduction For low-frequency circuits, resistors and capacitors can be analyzed as ideal devices. However, in high-frequency circuits, these two devices will not be "ideal". Today, our main discussion is about the issue of AC capacitors, which are commonly known as AC coupling capacitors. Their main function is to filter out the DC component of the signal, which is symmetrical about the X-axis...
    more
  • Why choose gel batteries?

    Why choose gel batteries?

    Aug , 22 2023
    The colloidal lead-acid battery is an improvement of the ordinary lead-acid battery with liquid electrolyte. The sulfuric acid electrolyte is replaced by a colloidal electrolyte, and the safety, power storage, discharge performance, and service life are improved compared with the ordinary battery. The colloidal lead-acid battery adopts a gel-like electrolyte; no free liquid is inside. Under the sa...
    more
  • What are the characteristics of industrial UPS power supply

    What are the characteristics of industrial UPS power supply

    Aug , 29 2023
    Industrial UPS power supplies need to focus on the ability to operate in high-temperature environments. The design of components must adapt to the operational requirements of the industrial environment, adapt to high temperature and humidity, and also be able to cope with the corrosion of corrosive gases on the system. Under various operating conditions and continuous full load operation, industri...
    more
  • UPS power supply power supply method and daily use precautions

    UPS power supply power supply method and daily use precautions

    Aug , 29 2023
    Today, whether it is a computer room or a data center, UPS power supply has played a vital position. When the UPS power supply is power supply in the municipal power, it is the role of the voltage regulator and filter to ensure the normal operation of the equipment; when the municipal power is interrupted, it can provide it by providing its DC power supply part (battery pack, diesel generator, etc...
    more
  • Important performance of the battery

    Important performance of the battery

    Sep , 04 2023
    1, electrical performance: (1) Rated capacity: 0.5C discharge, single battery discharge time is not less than 2h, battery pack discharge time is not less than 108min (95%); (2) 1C discharge capacity: 1C discharge, single battery discharge time is not less than 57min (95%), battery pack discharge time is not less than 54min (90%); (3) Low temperature discharge capacity: 0.5C discharge at -20℃, the ...
    more
  • Why only online UPS topology provides mission critical load protection

    Why only online UPS topology provides mission critical load protection

    Sep , 09 2023
    Why does only online UPS topology provides mission critical load protection? Modern, static UPS systems are broadly classified into three design architectures: on-line, off-line and line interactive. This post describes and compares the three types and explains why – for truly critical loads – online ups topology is the only acceptable approach. Facility executives today face increased demands for...
    more
  • Interface level standards between digital systems

    Interface level standards between digital systems

    Sep , 09 2023
    Preface When we constrain the FPGA project, we often see such level standards, such as LVCOM18, LVCOS25, LVDS, LVDS25, etc. In fact, these are a series of level standards, in order to have a deeper understanding of the level standards, the following excerpts from the book "The FPGA Way" for the explanation of the level standards to understand. Dual Threshold Standard The so-called dual-threshold s...
    more
first page << 1 ... 14 15 16 17 18 ... 23 >> last page

a total of23 pages

Are you looking for more information about EverExceed's  professional products and solutions?  Our expert team is always here to help. Please fill in the form and our sales representative will contact you shortly. EverExceed | Empower, Energize, Exceed the Energy you Expect forever.
copyright © 2024 EverExceed Industrial Co., Ltd.all rights reserved.
leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact