Blog
  • Lithium battery energy storage safety approach

    Lithium battery energy storage safety approach

    Dec , 01 2023
    1. Optimization design: In the design of lithium-ion energy storage system, the use environment and workload in various cases should be considered, and the structure, layout, heat dissipation and protection measures of the battery pack should be reasonably designed. 2, improve the manufacturing process: the manufacturing process is one of the important factors affecting the safety of lithium-ion e...
    more
  • Explanation of inverter harmonic control, increasing internal resistance of inverter power supply

    Explanation of inverter harmonic control, increasing internal resistance of inverter power supply

    Nov , 29 2023
    Due to its small size, light weight, low cost, and high efficiency, inverter power sources are highly favored in various production fields, especially in fields such as fans, water pumps, and transmission systems. Although the application of inverter power has produced significant energy-saving effects, the accompanying harmonic problems cannot be ignored. Inverter harmonic control instructions Th...
    more
  • What is the difference between UPS linear load and non linear load?

    What is the difference between UPS linear load and non linear load?

    Nov , 29 2023
    AC electrical loads are referred to either as linear or non linear load depending on how they draw current from the mains power supply waveform. Linear Load UPS loads where the voltage and current waveforms are sinusoidal. The current at any time is proportional to voltage. Linear load is: POWER FACTOR IMPROVEMENT CAPACITORS, INDESCENT LAMPS, HEATERS ETC Non Linear Load Applies to those UPS loads ...
    more
  • Comparison of advantages and disadvantages between half bridge circuit and full bridge circuit

    Comparison of advantages and disadvantages between half bridge circuit and full bridge circuit

    Nov , 25 2023
    The form of the half bridge inverter power conversion main circuit is shown in the following figure: By analyzing the withstand voltage of the switch tube and the primary voltage of the transformer when two switch tubes are alternately turned on and off using a sequential circuit, it is known that the required withstand voltage of the switch tube is Vac; The primary voltage of the transformer is 1...
    more
  • EMC classification and selection of UPS, using shielded cables

    EMC classification and selection of UPS, using shielded cables

    Nov , 25 2023
    Introduction to UPS and EMC Uninterruptible power supply (UPS), as a constant frequency, stable voltage, pure, and uninterrupted high-quality power supply, is widely used in various places with high requirements for power quality and continuity, such as personal, commercial, light industry, and industrial areas. When selecting UPS for various scenarios mentioned above, the core focus is mainly on ...
    more
  • Lead-acid battery leakage causes and prevention

    Lead-acid battery leakage causes and prevention

    Nov , 25 2023
    1. Battery leakage 1.1 Causes 1) Structural seal damage in the production process, such as defects in the welding or bonding surface of the pole and shell that are not found in time, resulting in leakage in use. 2) The apparent or invisible damage to the battery shell caused by improper operation during transportation or installation is not eliminated in time. 3) The charging setting is unreasonab...
    more
  • Causes and prevention of lead-acid battery bulge

    Causes and prevention of lead-acid battery bulge

    Nov , 25 2023
    1. The battery is bulging 1.1 Causes 1) Overcharge 2) Ambient high temperature 3) Thermal runaway 4) Individual monomers in the series circuit are not found in time, resulting in overcharging of other batteries 1.2 Prevention 1) The BSB system is installed to intelligently manage the charging of the battery itself and effectively prevent the overcharging of the battery. 2) Secondly, the BMS system...
    more
  • What is the ups power factor?

    What is the ups power factor?

    Nov , 17 2023
    Power factor (pf) is the difference between actual energy consumed and the apparent powerin an AC circuit. It will calculate as a decimal or percentage between 0-1 pf and 0-100% i.e. 0.9 pF = 90%. UPS input power factor The UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of power supply, but also a load on the utility power source. It means the ...
    more
  • What is single phase ups?

    What is single phase ups?

    Nov , 17 2023
    Single phase UPS has a single input and output source to the electrical equipment. With just one sinewave voltage, it only requires two wires to complete the circuit, one conductor and one neutral. Single phase UPS uninterruptible power supplies typically cover requirements up to 30 kVA. They are for servers, telecoms or computer systems, and network switches. Also they are along with any device t...
    more
first page << 1 ... 15 16 17 18 19 ... 67 >> last page

a total of67 pages

Are you looking for more information about EverExceed's  professional products and solutions?  Our expert team is always here to help. Please fill in the form and our sales representative will contact you shortly. EverExceed | Empower, Energize, Exceed the Energy you Expect forever.
copyright © 2025 Shenzhen EverExceed Industrial Co., Ltd.all rights reserved.
leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact