Blog
  • Causes of vulcanization in lead-acid batteries

    Causes of vulcanization in lead-acid batteries

    Mar , 08 2024
    A lead-acid battery is a common type of battery in which the positive and negative electrodes are composed of lead oxide (PbO2) and sponge lead (Pb), respectively, and the electrolyte is a sulfuric acid solution. Vulcanization is an unavoidable chemical reaction during the use of lead-acid batteries, which may lead to reduced battery capacity and shortened life. The following are the conditions an...
    more
  • What do you need to pay attention to when replacing lead acid with lithium in UPS applications?

    What do you need to pay attention to when replacing lead acid with lithium in UPS applications?

    Mar , 22 2024
    Understand battery characteristics: Before you start switching, be sure to understand the characteristics and operating requirements of lithium batteries. Compared with lead-acid batteries, lithium batteries have a higher energy density and faster charging speed. However, they are also more sensitive and require special charge and discharge management. Select the right lithium battery: Select the ...
    more
  • Why is lithium battery suitable for UPS battery?

    Why is lithium battery suitable for UPS battery?

    Mar , 22 2024
    1. High energy density: Lithium batteries have high energy density, that is, batteries can store more energy per unit mass. This means that the relatively small size and weight of lithium batteries can store more power. For UPS applications, this is important because it means that lithium batteries can provide longer backup times. 2. Long cycle life: The life of lithium batteries is usually longer...
    more
  • Four installation methods for disconnecting inverters from  the power grid and the use of dedicated sockets

    Four installation methods for disconnecting inverters from the power grid and the use of dedicated sockets

    Mar , 30 2024
    As we mentioned earlier, there are multiple methods to disconnect the inverter from the grid, but in the next section, we will focus on four common methods for RV inverter installation. Four installation methods for disconnecting inverters from the power grid 1. Direct connection Connecting your RV inverter directly to the AC distribution system of the RV through a conversion switch may be the mos...
    more
  • Impact of high temperature on battery safety performance

    Impact of high temperature on battery safety performance

    Mar , 30 2024
    Lithium battery temperature is too high, more than 45℃ Lithium-ion batteries are more and more widely used in people's production and life, which makes its temperature environment become the main point of concern, relatively speaking, lithium batteries are easier to produce safety problems in high temperature environment, therefore, it is necessary to test the high temperature performance of lithi...
    more
  • Advantages of Solar Gel batteries

    Advantages of Solar Gel batteries

    Apr , 02 2024
    Are Gel Batteries Better For Solar? The modern gel battery was invented in 1957. Gel batteries are one of two sealed lead acid batteries, the other being an AGM battery. Sealed lead acid batteries are distinct from other lead acid batteries in that they are maintenance-free What’s in a gel battery? A gel battery is a dry battery since it doesn’t use a liquid electrolyte. In a gel battery, the elec...
    more
  • Is DC-DC converter suitable for railway applications,  powered directly by batteries

    Is DC-DC converter suitable for railway applications, powered directly by batteries

    Apr , 02 2024
    DC/DC power converters are suitable for harsh mechanical and electrical environments in traction vehicles and locomotive applications. It has an ultra wide input voltage range from 16V to 160V and covers all input power systems in railway applications, including 24V, 28V, 36V, 48V, 72V, 96V, and 110VDC. Due to the increase in onboard electronic systems, the use of ultra wide input voltage converte...
    more
  • THE RELATIONSHIP BETWEEN APPARENT POWER, ACTIVE POWER, AND REACTIVE POWER

    THE RELATIONSHIP BETWEEN APPARENT POWER, ACTIVE POWER, AND REACTIVE POWER

    Apr , 20 2024
    The apparent power, active power, and reactive power meet the following triangular relationships: Figure (1): Schematic diagram of the power triangle S:Apparent power S 2 =P 2 + Q 2 Q:Reactive power P = S *cosφ
    more
  • Long-term storage methods for lithium batteries and storage requirements for lithium iron phosphate batteries

    Long-term storage methods for lithium batteries and storage requirements for lithium iron phosphate batteries

    Apr , 20 2024
    What impact will the lithium battery have after being put aside for a long time? When the lithium battery is idle, due to the nature of the battery itself, self-discharge, passivation of positive and negative electrode materials, electrolyte decomposition and other phenomena will occur. The instability of the negative SEI will lead to the rapid decline of the negative active substance, which is ea...
    more
  • What is the impact of low temperature on lithium batteries and solutions

    What is the impact of low temperature on lithium batteries and solutions

    Apr , 20 2024
    The use of lithium batteries in low battery temperature environments is limited. In addition to a severe drop in discharge capacity, lithium batteries cannot be charged when the battery temperature is low. When the battery is charged at low temperature, the lithium ion embedment on the battery graphite electrode and the lithium plating reaction exist simultaneously and compete with each other. Und...
    more
  • Causes, effects and measures of common problems of photovoltaic modules

    Causes, effects and measures of common problems of photovoltaic modules

    Apr , 26 2024
    First. Excessively high/low temperature Excessively high or low PV module temperatures can negatively affect the performance of the PV power system. The following are the causes and effects as well as the corresponding measures: 1. Causes of excessive temperature: solar radiation, heat conduction, shadow coverage, etc. Impact: Reduces the conversion efficiency of the module. Excessive temperature ...
    more
  • Measures to suppress harmonics

    Measures to suppress harmonics

    May , 11 2024
    The fundamental cause of harmonic generation is due to nonlinear loads. When the current flows through the load and does not have a linear relationship with the applied voltage, it forms a non sinusoidal current, resulting in harmonics. The suppression of harmonics in the power system is to reduce or eliminate the harmonic current injected into the system, in order to control the harmonic voltage ...
    more
first page << 1 ... 16 17 18 19 20 >> last page

a total of20 pages